How do I resuspend my oligo to obtain 100uMolar conc?

There is a quick method to calculate how to elute your dry oligo to a 100uMolar concentration, which is the concentration IDT recommends for your stock concentration.

To generate a 100uMolar concentration you need to take the number of nanomoles of oligo in your tube times a factor of ten, then the resulting number is the number of microliters of buffer or water to add to your tube to create a 100uMolar stock concentration.

For example, since you have 28.4nMoles, it would be: (28.4)(10) = 284uLiters of buffer or water to add to your tube to create a 100uMolar stock concentration.